In our quality control laboratory we do control permanently the following parameters:
Mechanical properties:
- Tensile strength (S2) (according to DIN 53504) - Elongation at break (according to DIN 53504) - Modulus 300% (according to DIN 53504) - Hardness (according to DIN 53504) - Tear strength (according to DIN ISO 34-1)
Rheological properties:
- Mooney viscosity (ML1+4; 100°C) (according to DIN 53523) - Rheometer Monsanto 2000 E (according to DIN 53529) - Minimum torque - T10 - T90 - Maximum torque
On special demands we or our German main company can perform some other examinations like:
Mechanical properties:
- Rebound Resilience (according to DIN 53512) - Specific gravity (according to DIN ISO 1183) - Abrasion (according to DIN 53516) - Compression set 72 h RT (according to DIN ISO 815) - Compression set 22 h 70°C (according to DIN ISO 815) - Compression set 22 h 100°C (according to DIN ISO 815) - Compression set 72 h - 10 (according to DIN ISO 815)
Resistance against hot air (according to DIN 53508):
- Change in tensile strength (according to DIN 53504) - Change in elongation at break (according to DIN 53504) - Hardness change (according to DIN 53505)
Resistance against IRM 902 (according to DIN ISO 1817):
- Change in tensile strength (according to DIN 53504) - Change in elongation at break (according to DIN 53504) - Hardness change (according to DIN 53505) - Weight change (according to DIN ISO 1817) - Volume change (according to DIN ISO 1817)
Ozone resistance (according to DIN 53509):
- Elongation - Crack rating
Electrical Properties (according to DIN 53482):
- Volume resistance at 1000 V - Surface resistance at 1000 V
Low temperature resistance (according to according to ISO 11357):
- Static glass transition temperature
To assure the constant quality of our products and services we introduced the ISO 9001 system (certified by TUV.)